Solar production by month
kWh made by 1 kW of panels in an average Indiana year. July is the best month (141 kWh) and December the weakest (53 kWh).
| Month | Peak sun hours a day | kWh per kW |
|---|---|---|
| January | 2.3 | 62 |
| February | 2.9 | 66 |
| March | 4.2 | 104 |
| April | 5.0 | 116 |
| May | 5.8 | 132 |
| June | 6.2 | 126 |
| July | 6.1 | 141 |
| August | 5.7 | 133 |
| September | 5.0 | 116 |
| October | 3.6 | 91 |
| November | 2.5 | 61 |
| December | 2.0 | 53 |
Solar output across Indiana
Yearly kWh per kW at each NREL weather station. Class I stations have the most complete measured record; Class II are reliable but with more gaps filled.
| Location | kWh per kW a year | Peak sun hours | Data class |
|---|---|---|---|
| Evansville Regional Airport | 1,342 | 4.7 | I |
| Indianapolis Intl Airport | 1,320 | 4.6 | I |
| Fort Wayne Intl Airport | 1,255 | 4.3 | I |
| South Bend Michiana Rgnl Airport | 1,235 | 4.2 | I |
| Grissom Arb | 1,202 | 4.1 | II |
| Delaware Co Johnson | 1,168 | 4.0 | II |
| Lafayette Purdue Univ Airport | 1,147 | 4.0 | II |
| Terre Haute Hulman Regional Airport | 1,126 | 3.9 | II |
| Monroe Co | 1,113 | 3.9 | II |
Panels for the average Indiana home
The average home here used 901 kWh a month in 2024 (EIA), 10,812 kWh a year. At 1,202 kWh per kW, covering all of it takes about 9.0 kW, or 21 panels of 430 W, roughly 452 sq ft of panels. Run your own numbers with the solar panel calculator.
What "peak sun hours" means
One peak sun hour is 1,000 W of sunlight on a square metre for an hour, 1 kWh/m². A day with 5 peak sun hours delivers as much energy as 5 hours of full sun, spread over the whole day. Tilting panels toward the sun collects more than flat ground, which is why the roof figure is higher than the flat (GHI) figure.
States with similar sun
| State | Peak sun hours | kWh per kW a year |
|---|---|---|
| Wisconsin | 4.1 | 1,210 |
| Vermont | 4.1 | 1,208 |
| Pennsylvania | 4.2 | 1,203 |
| Indiana | 4.1 | 1,202 |
| Minnesota | 4.1 | 1,198 |
| Massachusetts | 4.1 | 1,194 |
| New York | 4.1 | 1,189 |
Method: NREL TMY3 typical-year weather data (1991–2005) for every Class I and II station, modelled with the PVWatts method in pvlib: 1 kW of panels facing south at 20°, 14% system losses, 96% inverter, DC/AC ratio 1.2. State figure = median station. Real systems vary with direction, shade and local weather. All states.