Solar production by month
kWh made by 1 kW of panels in an average Nevada year. June is the best month (172 kWh) and December the weakest (85 kWh).
| Month | Peak sun hours a day | kWh per kW |
|---|---|---|
| January | 3.5 | 88 |
| February | 4.6 | 100 |
| March | 5.3 | 131 |
| April | 6.5 | 152 |
| May | 7.1 | 165 |
| June | 7.8 | 172 |
| July | 7.8 | 171 |
| August | 7.5 | 165 |
| September | 6.6 | 148 |
| October | 5.4 | 128 |
| November | 4.2 | 98 |
| December | 3.2 | 85 |
Solar output across Nevada
Yearly kWh per kW at each NREL weather station. Class I stations have the most complete measured record; Class II are reliable but with more gaps filled.
| Location | kWh per kW a year | Peak sun hours | Data class |
|---|---|---|---|
| Mercury Desert Rock Airport | 1,741 | 6.3 | I |
| Las Vegas McCarran Intl Airport | 1,730 | 6.3 | I |
| Tonopah Airport | 1,690 | 6.0 | I |
| Fallon NAAS | 1,664 | 6.0 | II |
| Reno Tahoe International Airport | 1,603 | 5.7 | I |
| Ely Yelland Field | 1,602 | 5.6 | I |
| Nellis AFB | 1,590 | 5.8 | II |
| Winnemucca Municipal Airport | 1,573 | 5.6 | I |
| Lovelock Derby Field | 1,560 | 5.6 | I |
| Elko Municipal Airport | 1,533 | 5.4 | II |
Panels for the average Nevada home
The average home here used 930 kWh a month in 2024 (EIA), 11,160 kWh a year. At 1,603 kWh per kW, covering all of it takes about 7.0 kW, or 17 panels of 430 W, roughly 366 sq ft of panels. Run your own numbers with the solar panel calculator.
What "peak sun hours" means
One peak sun hour is 1,000 W of sunlight on a square metre for an hour, 1 kWh/m². A day with 5 peak sun hours delivers as much energy as 5 hours of full sun, spread over the whole day. Tilting panels toward the sun collects more than flat ground, which is why the roof figure is higher than the flat (GHI) figure.
States with similar sun
| State | Peak sun hours | kWh per kW a year |
|---|---|---|
| Arizona | 6.3 | 1,715 |
| New Mexico | 6.1 | 1,706 |
| Nevada | 5.8 | 1,603 |
| California | 5.6 | 1,586 |
| Utah | 5.5 | 1,559 |
| Hawaii | 5.5 | 1,541 |
Method: NREL TMY3 typical-year weather data (1991–2005) for every Class I and II station, modelled with the PVWatts method in pvlib: 1 kW of panels facing south at 20°, 14% system losses, 96% inverter, DC/AC ratio 1.2. State figure = median station. Real systems vary with direction, shade and local weather. All states.