Solar production by month
kWh made by 1 kW of panels in an average Ohio year. July is the best month (139 kWh) and December the weakest (47 kWh).
| Month | Peak sun hours a day | kWh per kW |
|---|---|---|
| January | 2.2 | 60 |
| February | 2.9 | 69 |
| March | 4.0 | 102 |
| April | 5.0 | 119 |
| May | 5.5 | 136 |
| June | 5.9 | 134 |
| July | 6.0 | 139 |
| August | 5.2 | 121 |
| September | 4.7 | 106 |
| October | 3.5 | 87 |
| November | 2.4 | 59 |
| December | 1.9 | 47 |
Solar output across Ohio
Yearly kWh per kW at each NREL weather station. Class I stations have the most complete measured record; Class II are reliable but with more gaps filled.
| Location | kWh per kW a year | Peak sun hours | Data class |
|---|---|---|---|
| Toledo Express Airport | 1,264 | 4.3 | I |
| Dayton International Airport | 1,252 | 4.3 | I |
| Columbus Port Columbus Intl Airport | 1,224 | 4.2 | I |
| Mansfield Lahm Municipal Airport | 1,214 | 4.1 | I |
| Cleveland Hopkins Intl Airport | 1,205 | 4.1 | I |
| Cincinnati Municipal Airport Lunki | 1,189 | 4.1 | II |
| Akron Akron-Canton Reg Airport | 1,179 | 4.0 | I |
| Ohio State Universi | 1,177 | 4.1 | II |
| Dayton Wright Patterson AFB | 1,173 | 4.0 | II |
| Youngstown Regional Airport | 1,161 | 4.0 | I |
| Findlay Airport | 1,159 | 4.0 | II |
| Burke Lakefront | 1,118 | 3.8 | II |
| Zanesville Municipal Airport | 1,070 | 3.7 | II |
Panels for the average Ohio home
The average home here used 846 kWh a month in 2024 (EIA), 10,152 kWh a year. At 1,179 kWh per kW, covering all of it takes about 8.6 kW, or 21 panels of 430 W, roughly 452 sq ft of panels. Run your own numbers with the solar panel calculator.
What "peak sun hours" means
One peak sun hour is 1,000 W of sunlight on a square metre for an hour, 1 kWh/m². A day with 5 peak sun hours delivers as much energy as 5 hours of full sun, spread over the whole day. Tilting panels toward the sun collects more than flat ground, which is why the roof figure is higher than the flat (GHI) figure.
States with similar sun
| State | Peak sun hours | kWh per kW a year |
|---|---|---|
| Massachusetts | 4.1 | 1,194 |
| New York | 4.1 | 1,189 |
| West Virginia | 4.1 | 1,183 |
| Ohio | 4.1 | 1,179 |
| Maine | 4.0 | 1,177 |
| Michigan | 4.0 | 1,169 |
| New Hampshire | 4.0 | 1,163 |
Method: NREL TMY3 typical-year weather data (1991–2005) for every Class I and II station, modelled with the PVWatts method in pvlib: 1 kW of panels facing south at 20°, 14% system losses, 96% inverter, DC/AC ratio 1.2. State figure = median station. Real systems vary with direction, shade and local weather. All states.