Home › Compatibility › Canadian Solar CS6.2-48TM-445H + EG4 18kPV-12LV

Canadian Solar CS6.2-48TM-445H with EG4 18kPV-12LV

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 6–16 panels work. The longest string reaches 599 V on the coldest morning, under the 600 V inverter limit. One EG4 18kPV-12LV takes up to 3 strings of 14: 42 panels, 18.69 kWp DC, DC/AC ratio 1.56.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C6–15 panels per string (best 13)
Chicago, IL−21 °C6–15 panels per string (best 14)
Denver, CO−23.6 °C6–15 panels per string (best 14)
Atlanta, GA−9.5 °C6–16 panels per string (best 14)
Dallas, TX−7.1 °C6–16 panels per string (best 14)
Phoenix, AZ1.3 °C6–16 panels per string (best 15)
Miami, FL5.9 °C6–16 panels per string (best 15)

Common system sizes

How Canadian Solar CS6.2-48TM-445H panels lay out on the EG4 18kPV-12LV for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW131 string of 13 on 1 inverter5.79 kWp0.48
About 8 kW182 strings of 9 on 1 inverter8.01 kWp0.67
About 10 kW222 strings of 11 on 1 inverter9.79 kWp0.82