Home › Compatibility › Heliene 108HC-430 M10 NTYP SL + Sol-Ark 12K-2P-LL

Heliene 108HC-430 M10 NTYP SL with Sol-Ark 12K-2P-LL

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 6–12 panels work. The longest string reaches 500 V on the coldest morning, under the 500 V inverter limit. One Sol-Ark 12K-2P-LL takes up to 4 strings of 11: 44 panels, 18.92 kWp DC, DC/AC ratio 1.58.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C6–11 panels per string (best 11)
Chicago, IL−21 °C6–11 panels per string (best 11)
Denver, CO−23.6 °C6–11 panels per string (best 11)
Atlanta, GA−9.5 °C6–12 panels per string (best 11)
Dallas, TX−7.1 °C6–12 panels per string (best 11)
Phoenix, AZ1.3 °C6–12 panels per string (best 12)
Miami, FL5.9 °C6–12 panels per string (best 12)

Common system sizes

How Heliene 108HC-430 M10 NTYP SL panels lay out on the Sol-Ark 12K-2P-LL for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW142 strings of 7 on 1 inverter6.02 kWp0.50
About 8 kW191 × 10 + 1 × 9 panels on 1 inverter8.17 kWp0.68
About 10 kW231 × 12 + 1 × 11 panels on 1 inverter9.89 kWp0.82