Home › Compatibility › Jinko Solar Tiger Neo JKM580N-72HL4-BDV + APsystems QS1

Jinko Solar Tiger Neo JKM580N-72HL4-BDV with APsystems QS1

Compatibility and string sizing for this panel and microinverter, calculated from both datasheets.

!

Compatible, with a caution

Yes. Each QS1 takes 4 panels, and up to 3 units fit on one 20 A branch circuit (12 panels). DC/AC ratio 1.93. Check the Input current; Module power pairing below.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C, bifacial gain 10%.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C4 panels per unit (check: MPPT window, cold day)
Chicago, IL−21 °C4 panels per unit (check: MPPT window, cold day)
Denver, CO−23.6 °C4 panels per unit (check: MPPT window, cold day)
Atlanta, GA−9.5 °C4 panels per unit (check: Input current)
Dallas, TX−7.1 °C4 panels per unit (check: Input current)
Phoenix, AZ1.3 °C4 panels per unit (check: Input current)
Miami, FL5.9 °C4 panels per unit (check: Input current)

Common system sizes

How Jinko Solar Tiger Neo JKM580N-72HL4-BDV panels lay out on the APsystems QS1 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW103 × QS1 on 1 branch circuit5.80 kWp1.61
About 8 kW144 × QS1 on 2 branch circuits8.12 kWp1.69
About 10 kW175 × QS1 on 2 branch circuits9.86 kWp1.64