Meyer Burger Meyer Burger White 400W with EG4 FlexBOSS21
Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.
Compatible
Yes. At a −10 °C record low and a 40 °C hot day, strings of 6–12 panels work. The longest string reaches 580 V on the coldest morning, under the 600 V inverter limit. One EG4 FlexBOSS21 takes up to 5 strings of 10: 50 panels, 20.00 kWp DC, DC/AC ratio 1.25.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- Voc on the coldest morning44.7 V × (1 + -0.233%/°C × (−10 − 25)) = 48.35 V per panel.
- Vmp on the hottest afternoonCells reach 72.8 °C (40 °C air plus the NMOT rise), so Vmp drops from 38.2 V to 33.04 V (Vmp coefficient taken as Pmax − Isc coefficient).
- Longest string600 V inverter limit ÷ 48.35 V = 12 panels.
- Shortest string120 V MPPT minimum ÷ 33.04 V = 4 panels; start-up voltage needs 6.
- Strings per MPPTHot-day Isc 11.29 A per string, so the MPPT inputs take 2 + 2 + 1 string(s).
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 6–11 panels per string (best 10) |
| Chicago, IL | −21 °C | 6–12 panels per string (best 10) |
| Denver, CO | −23.6 °C | 6–12 panels per string (best 10) |
| Atlanta, GA | −9.5 °C | 6–12 panels per string (best 10) |
| Dallas, TX | −7.1 °C | 6–12 panels per string (best 10) |
| Phoenix, AZ | 1.3 °C | 6–12 panels per string (best 10) |
| Miami, FL | 5.9 °C | 6–12 panels per string (best 10) |
Common system sizes
How Meyer Burger Meyer Burger White 400W panels lay out on the EG4 FlexBOSS21 for one, two and four fully loaded inverters, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| 1 inverter, fully loaded | 50 | 5 strings of 10 on 1 inverter | 20.00 kWp | 1.25 |
| 2 inverters, fully loaded | 100 | 10 strings of 10 on 2 inverters | 40.00 kWp | 1.25 |
| 4 inverters, fully loaded | 200 | 20 strings of 10 on 4 inverters | 80.00 kWp | 1.25 |