Home › Compatibility › Meyer Burger Meyer Burger White 400W + Sol-Ark Limitless 15K-2P

Meyer Burger Meyer Burger White 400W with Sol-Ark Limitless 15K-2P

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 5–10 panels work. The longest string reaches 483 V on the coldest morning, under the 500 V inverter limit. One Sol-Ark Limitless 15K-2P takes up to 5 strings of 10: 50 panels, 20.00 kWp DC, DC/AC ratio 1.33.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C5–9 panels per string (best 9)
Chicago, IL−21 °C5–10 panels per string (best 10)
Denver, CO−23.6 °C5–10 panels per string (best 10)
Atlanta, GA−9.5 °C5–10 panels per string (best 10)
Dallas, TX−7.1 °C5–10 panels per string (best 10)
Phoenix, AZ1.3 °C5–10 panels per string (best 10)
Miami, FL5.9 °C5–10 panels per string (best 10)

Common system sizes

How Meyer Burger Meyer Burger White 400W panels lay out on the Sol-Ark Limitless 15K-2P for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW151 × 8 + 1 × 7 panels on 1 inverter6.00 kWp0.40
About 8 kW202 strings of 10 on 1 inverter8.00 kWp0.53
About 10 kW251 × 9 + 2 × 8 panels on 1 inverter10.00 kWp0.67