Home › Compatibility › Qcells Q.PEAK DUO XL-G11S.3/BFG 590 + CPS (Chint Power) SCA50KTL-DO/US-480

Qcells Q.PEAK DUO XL-G11S.3/BFG 590 with CPS (Chint Power) SCA50KTL-DO/US-480

Compatibility and string sizing for this panel and string inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 7–17 panels work. The longest string reaches 997 V on the coldest morning, under the 1000 V inverter limit. One CPS (Chint Power) SCA50KTL-DO/US-480 takes up to 8 strings of 17: 136 panels, 80.24 kWp DC, DC/AC ratio 1.60.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C, bifacial gain 9.5%.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C7–16 panels per string (best 16)
Chicago, IL−21 °C7–16 panels per string (best 16)
Denver, CO−23.6 °C7–16 panels per string (best 16)
Atlanta, GA−9.5 °C7–17 panels per string (best 17)
Dallas, TX−7.1 °C7–17 panels per string (best 17)
Phoenix, AZ1.3 °C7–17 panels per string (best 17)
Miami, FL5.9 °C7–17 panels per string (best 17)

Common system sizes

How Qcells Q.PEAK DUO XL-G11S.3/BFG 590 panels lay out on the CPS (Chint Power) SCA50KTL-DO/US-480 for one, two and four fully loaded inverters, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
1 inverter, fully loaded1449 strings of 16 on 1 inverter84.96 kWp1.70
2 inverters, fully loaded28818 strings of 16 on 2 inverters169.92 kWp1.70
4 inverters, fully loaded57636 strings of 16 on 4 inverters339.84 kWp1.70