Home › Compatibility › REC Alpha Pure-RX REC470AA + Sol-Ark 30K-3P-208V

REC Alpha Pure-RX REC470AA with Sol-Ark 30K-3P-208V

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 4–7 panels work. The longest string reaches 498 V on the coldest morning, under the 550 V inverter limit. One Sol-Ark 30K-3P-208V takes up to 8 strings of 7: 56 panels, 26.32 kWp DC, DC/AC ratio 0.88.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C4–7 panels per string (best 7)
Chicago, IL−21 °C4–7 panels per string (best 7)
Denver, CO−23.6 °C4–7 panels per string (best 7)
Atlanta, GA−9.5 °C4–7 panels per string (best 7)
Dallas, TX−7.1 °C4–7 panels per string (best 7)
Phoenix, AZ1.3 °C4–7 panels per string (best 7)
Miami, FL5.9 °C4–8 panels per string (best 8)

Common system sizes

How REC Alpha Pure-RX REC470AA panels lay out on the Sol-Ark 30K-3P-208V for one, two and four fully loaded inverters, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
1 inverter, fully loaded568 strings of 7 on 1 inverter26.32 kWp0.88
2 inverters, fully loaded11216 strings of 7 on 2 inverters52.64 kWp0.88
4 inverters, fully loaded22432 strings of 7 on 4 inverters105.28 kWp0.88