Home › Compatibility › REC Alpha Pure-RX REC470AA + SolarEdge SE3000H-US

REC Alpha Pure-RX REC470AA with SolarEdge SE3000H-US

Compatibility and string sizing for this panel and solaredge inverter, calculated from both datasheets.

✓

Compatible

Yes, with the SolarEdge S500B optimizer on every panel. Strings of 6–9 panels work (best 9), each delivering up to 4,650 W. One SolarEdge SE3000H-US takes up to 1 string of 9: 9 panels, 4.23 kWp DC, DC/AC ratio 1.41.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C6–9 panels per string (best 9)
Chicago, IL−21 °C6–9 panels per string (best 9)
Denver, CO−23.6 °C6–9 panels per string (best 9)
Atlanta, GA−9.5 °C6–9 panels per string (best 9)
Dallas, TX−7.1 °C6–9 panels per string (best 9)
Phoenix, AZ1.3 °C6–9 panels per string (best 9)
Miami, FL5.9 °C6–9 panels per string (best 9)

Common system sizes

How REC Alpha Pure-RX REC470AA panels lay out on the SolarEdge SE3000H-US for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW131 × 7 + 1 × 6 panels on 2 inverters6.11 kWp1.02
About 8 kW171 × 9 + 1 × 8 panels on 2 inverters7.99 kWp1.33
About 10 kW213 strings of 7 on 3 inverters9.87 kWp1.10