REC REC405AA Pure with EG4 FlexBOSS21
Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.
Compatible
Yes. At a −10 °C record low and a 40 °C hot day, strings of 5–11 panels work. The longest string reaches 582 V on the coldest morning, under the 600 V inverter limit. One EG4 FlexBOSS21 takes up to 5 strings of 9: 45 panels, 18.23 kWp DC, DC/AC ratio 1.14.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- Voc on the coldest morning48.9 V × (1 + -0.233%/°C × (−10 − 25)) = 52.89 V per panel.
- Vmp on the hottest afternoonCells reach 71.2 °C (40 °C air plus the NMOT rise), so Vmp drops from 42.4 V to 36.71 V (Vmp coefficient taken as Pmax − Isc coefficient).
- Longest string600 V inverter limit ÷ 52.89 V = 11 panels.
- Shortest string120 V MPPT minimum ÷ 36.71 V = 4 panels; start-up voltage needs 5.
- Strings per MPPTHot-day Isc 10.46 A per string, so the MPPT inputs take 2 + 2 + 1 string(s).
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 5–10 panels per string (best 9) |
| Chicago, IL | −21 °C | 5–11 panels per string (best 9) |
| Denver, CO | −23.6 °C | 5–11 panels per string (best 9) |
| Atlanta, GA | −9.5 °C | 5–11 panels per string (best 9) |
| Dallas, TX | −7.1 °C | 5–11 panels per string (best 9) |
| Phoenix, AZ | 1.3 °C | 5–11 panels per string (best 9) |
| Miami, FL | 5.9 °C | 5–11 panels per string (best 9) |
Common system sizes
How REC REC405AA Pure panels lay out on the EG4 FlexBOSS21 for one, two and four fully loaded inverters, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| 1 inverter, fully loaded | 50 | 5 strings of 10 on 1 inverter | 20.25 kWp | 1.27 |
| 2 inverters, fully loaded | 100 | 10 strings of 10 on 2 inverters | 40.50 kWp | 1.27 |
| 4 inverters, fully loaded | 200 | 20 strings of 10 on 4 inverters | 81.00 kWp | 1.27 |