Home › Compatibility › REC REC405AA Pure + EG4 FlexBOSS21

REC REC405AA Pure with EG4 FlexBOSS21

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 5–11 panels work. The longest string reaches 582 V on the coldest morning, under the 600 V inverter limit. One EG4 FlexBOSS21 takes up to 5 strings of 9: 45 panels, 18.23 kWp DC, DC/AC ratio 1.14.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C5–10 panels per string (best 9)
Chicago, IL−21 °C5–11 panels per string (best 9)
Denver, CO−23.6 °C5–11 panels per string (best 9)
Atlanta, GA−9.5 °C5–11 panels per string (best 9)
Dallas, TX−7.1 °C5–11 panels per string (best 9)
Phoenix, AZ1.3 °C5–11 panels per string (best 9)
Miami, FL5.9 °C5–11 panels per string (best 9)

Common system sizes

How REC REC405AA Pure panels lay out on the EG4 FlexBOSS21 for one, two and four fully loaded inverters, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
1 inverter, fully loaded505 strings of 10 on 1 inverter20.25 kWp1.27
2 inverters, fully loaded10010 strings of 10 on 2 inverters40.50 kWp1.27
4 inverters, fully loaded20020 strings of 10 on 4 inverters81.00 kWp1.27