Home › Compatibility › REC REC420AA Pure-R + EG4 FlexBOSS21

REC REC420AA Pure-R with EG4 FlexBOSS21

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 4–9 panels work. The longest string reaches 579 V on the coldest morning, under the 600 V inverter limit. One EG4 FlexBOSS21 takes up to 5 strings of 8: 40 panels, 16.80 kWp DC, DC/AC ratio 1.05.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C4–9 panels per string (best 7)
Chicago, IL−21 °C4–9 panels per string (best 7)
Denver, CO−23.6 °C4–9 panels per string (best 7)
Atlanta, GA−9.5 °C4–9 panels per string (best 8)
Dallas, TX−7.1 °C4–9 panels per string (best 8)
Phoenix, AZ1.3 °C4–9 panels per string (best 8)
Miami, FL5.9 °C4–9 panels per string (best 8)

Common system sizes

How REC REC420AA Pure-R panels lay out on the EG4 FlexBOSS21 for one, two and four fully loaded inverters, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
1 inverter, fully loaded455 strings of 9 on 1 inverter18.90 kWp1.18
2 inverters, fully loaded9010 strings of 9 on 2 inverters37.80 kWp1.18
4 inverters, fully loaded18020 strings of 9 on 4 inverters75.60 kWp1.18