Home › Compatibility › REC REC420AA Pure-R + Tesla Powerwall 3

REC REC420AA Pure-R with Tesla Powerwall 3

Compatibility and string sizing for this panel and hybrid inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 2–8 panels work. The longest string reaches 514 V on the coldest morning, under the 550 V inverter limit. One Tesla Powerwall 3 takes up to 5 strings of 8: 40 panels, 16.80 kWp DC, DC/AC ratio 1.46.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C2–8 panels per string (best 8)
Chicago, IL−21 °C2–8 panels per string (best 8)
Denver, CO−23.6 °C2–8 panels per string (best 8)
Atlanta, GA−9.5 °C2–8 panels per string (best 8)
Dallas, TX−7.1 °C2–8 panels per string (best 8)
Phoenix, AZ1.3 °C2–8 panels per string (best 8)
Miami, FL5.9 °C2–8 panels per string (best 8)

Common system sizes

How REC REC420AA Pure-R panels lay out on the Tesla Powerwall 3 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW142 strings of 7 on 1 inverter5.88 kWp0.51
About 8 kW191 × 7 + 2 × 6 panels on 1 inverter7.98 kWp0.69
About 10 kW243 strings of 8 on 1 inverter10.08 kWp0.88