REC REC405AA Pure with Tesla Solar Inverter 7.6 kW
Compatibility and string sizing for this panel and string inverter, calculated from both datasheets.
Compatible
Yes. At a −10 °C record low and a 40 °C hot day, strings of 2–11 panels work. The longest string reaches 582 V on the coldest morning, under the 600 V inverter limit. One Tesla Solar Inverter 7.6 kW takes up to 4 strings of 10: 40 panels, 16.20 kWp DC, DC/AC ratio 2.13.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- Voc on the coldest morning48.9 V × (1 + -0.233%/°C × (−10 − 25)) = 52.89 V per panel.
- Vmp on the hottest afternoonCells reach 71.2 °C (40 °C air plus the NMOT rise), so Vmp drops from 42.4 V to 36.71 V (Vmp coefficient taken as Pmax − Isc coefficient).
- Longest string600 V inverter limit ÷ 52.89 V = 11 panels.
- Shortest string60 V MPPT minimum ÷ 36.71 V = 2 panels.
- Strings per MPPTHot-day Isc 10.46 A per string, so the MPPT inputs take 1 + 1 + 1 + 1 string(s).
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 2–10 panels per string (best 9) |
| Chicago, IL | −21 °C | 2–11 panels per string (best 9) |
| Denver, CO | −23.6 °C | 2–11 panels per string (best 9) |
| Atlanta, GA | −9.5 °C | 2–11 panels per string (best 10) |
| Dallas, TX | −7.1 °C | 2–11 panels per string (best 10) |
| Phoenix, AZ | 1.3 °C | 2–11 panels per string (best 10) |
| Miami, FL | 5.9 °C | 2–11 panels per string (best 10) |
Common system sizes
How REC REC405AA Pure panels lay out on the Tesla Solar Inverter 7.6 kW for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | 15 | 1 × 8 + 1 × 7 panels on 1 inverter | 6.08 kWp | 0.80 |
| About 8 kW | 20 | 2 strings of 10 on 1 inverter | 8.10 kWp | 1.07 |
| About 10 kW | 25 | 1 × 9 + 2 × 8 panels on 1 inverter | 10.12 kWp | 1.33 |