Home › Compatibility › REC REC420AA Pure-R + SolarEdge SE5000H-US
REC REC420AA Pure-R with SolarEdge SE5000H-US
Compatibility and string sizing for this panel and solaredge inverter, calculated from both datasheets.
✓
Compatible
Yes, with the SolarEdge S500B optimizer on every panel. Strings of 6–18 panels work (best 13), each delivering up to 5,700 W. One SolarEdge SE5000H-US takes up to 2 strings of 13: 18 panels, 7.56 kWp DC, DC/AC ratio 1.51.
How it's calculated
NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C.
- ✓ Module power420 W is within the S500B rating of 650 W.
- ✓ Max input voltageVoc at the record low is 64.3 V, within the 125 V optimizer limit.
- ✓ MPPT windowVmp stays inside 12.5–105 V from the coldest to the hottest day.
- ✓ Module short-circuit currentIsc 8.89 A is within the 15 A limit.
By climate
The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.
| City | Record low | Result |
|---|---|---|
| Minneapolis, MN | −27 °C | 6–18 panels per string (best 13) |
| Chicago, IL | −21 °C | 6–18 panels per string (best 13) |
| Denver, CO | −23.6 °C | 6–18 panels per string (best 13) |
| Atlanta, GA | −9.5 °C | 6–18 panels per string (best 13) |
| Dallas, TX | −7.1 °C | 6–18 panels per string (best 13) |
| Phoenix, AZ | 1.3 °C | 6–18 panels per string (best 13) |
| Miami, FL | 5.9 °C | 6–18 panels per string (best 13) |
Common system sizes
How REC REC420AA Pure-R panels lay out on the SolarEdge SE5000H-US for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.
| System | Panels | Layout | DC size | DC/AC |
|---|---|---|---|---|
| About 6 kW | 14 | 1 string of 14 on 1 inverter | 5.88 kWp | 1.18 |
| About 8 kW | 19 | 1 × 10 + 1 × 9 panels on 2 inverters | 7.98 kWp | 0.80 |
| About 10 kW | 24 | 2 strings of 12 on 2 inverters | 10.08 kWp | 1.01 |