Talesun BiPro TM7G54M-425 with SMA SB3.0-1SP-US-40

Compatibility and string sizing for this panel and string inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 4–14 panels work. The longest string reaches 583 V on the coldest morning, under the 600 V inverter limit.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C, bifacial gain 10%.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C4–13 panels per string (best 13)
Chicago, IL−21 °C4–14 panels per string (best 14)
Denver, CO−23.6 °C4–13 panels per string (best 13)
Atlanta, GA−9.5 °C4–14 panels per string (best 14)
Dallas, TX−7.1 °C4–14 panels per string (best 14)
Phoenix, AZ1.3 °C4–14 panels per string (best 14)
Miami, FL5.9 °C4–14 panels per string (best 14)

Common system sizes

How Talesun BiPro TM7G54M-425 panels lay out on the SMA SB3.0-1SP-US-40 for typical 6, 8 and 10 kW home systems, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
About 6 kW142 strings of 7 on 2 inverters5.95 kWp0.99
About 8 kW191 × 10 + 1 × 9 panels on 2 inverters8.07 kWp1.35
About 10 kW243 strings of 8 on 3 inverters10.20 kWp1.13