Home › Compatibility › Talesun BiPro TM7G54M-425 + Solis S6-GC50K-US

Talesun BiPro TM7G54M-425 with Solis S6-GC50K-US

Compatibility and string sizing for this panel and string inverter, calculated from both datasheets.

✓

Compatible

Yes. At a −10 °C record low and a 40 °C hot day, strings of 7–24 panels work. The longest string reaches 1,000 V on the coldest morning, under the 1000 V inverter limit. One Solis S6-GC50K-US takes up to 8 strings of 24: 192 panels, 81.60 kWp DC, DC/AC ratio 1.63.

How it's calculated

NEC 690.7 coefficient method with the datasheet values. Record low −10 °C, hottest day 40 °C, bifacial gain 10%.

By climate

The coldest morning sets the longest string. Record lows are ASHRAE extreme annual mean minimums; the hottest day is kept at 40 °C.

CityRecord lowResult
Minneapolis, MN−27 °C7–23 panels per string (best 23)
Chicago, IL−21 °C7–23 panels per string (best 23)
Denver, CO−23.6 °C7–23 panels per string (best 23)
Atlanta, GA−9.5 °C7–24 panels per string (best 24)
Dallas, TX−7.1 °C7–24 panels per string (best 24)
Phoenix, AZ1.3 °C7–24 panels per string (best 24)
Miami, FL5.9 °C7–24 panels per string (best 24)

Common system sizes

How Talesun BiPro TM7G54M-425 panels lay out on the Solis S6-GC50K-US for one, two and four fully loaded inverters, using the String Sizer's project calculator at the same −10 °C / 40 °C design temperatures.

SystemPanelsLayoutDC sizeDC/AC
1 inverter, fully loaded1928 strings of 24 on 1 inverter81.60 kWp1.63
2 inverters, fully loaded38416 strings of 24 on 2 inverters163.20 kWp1.63
4 inverters, fully loaded76832 strings of 24 on 4 inverters326.40 kWp1.63