Solar design tools for Qatar (Kahramaa)
The Tera Labs tools, set up for Qatar (Kahramaa): array voltage at 0 °C, 50 °C ambient, the 1,000 V or 1,500 V class, IEC 62548 string fuses and Kahramaa's capacity rule.
Qatar rules these tools apply
- Design temperatures. Kahramaa's specification gives no design temperature. 0 °C is a conservative minimum for Qatar, and equipment is checked at 50 °C ambient.
- Voltage limit. Kahramaa's Technical Specifications for the Connection of Solar PV Systems set no rooftop DC limit; PV cables are specified to IEC 62930 (1.5 kV DC). Pick the 1,000 V or 1,500 V class that matches your panels and inverter; the tool also checks the inverter's maximum DC input and the panel's maximum system voltage.
- String fuses. Outside Dubai the tools use the IEC 62548 check, written the same way as DEWA's DRRG 2.6.1: string fuses are needed when (strings in parallel − 1) × the panel's short-circuit current is above its maximum series fuse rating. gPV fuses are then rated between 1.5 and 2.4 × Isc and no higher than the panel's fuse rating. Some editions add a safety factor to Isc, so near the limit check the edition your authority uses.
- Capacity and scheme. Under BeSolar the system must not exceed the contracted demand approved in the building permit (Technical Specifications, section 1), up to 25 MW. Surplus is bought at 0.237 QAR/kWh and credited to later bills. Single- and two-phase inverters only up to 11 kW (section 5.9.8.5).
- Equipment. Use equipment from Kahramaa's approved materials list, installed by a Kahramaa-approved contractor. Kahramaa lists approved makers and series rather than every model, so the tools mark models in a named series as Kahramaa series (checked 26 Nov 2026); confirm the exact model.
Other markets: all Gulf solar tools.