Home › Guides
Solar design guides
Plain-English guides to the numbers behind solar design: string sizing, NEC voltage and wiring rules, peak sun hours and payback, each with worked examples from real equipment and US weather data.
String design
How to size a solar string (NEC 690.7, step by step)Cold-temperature Voc correction, max and min string length and MPPT current checks, with a worked Denver example.4 min readWhy solar panel voltage rises in cold weather, and how muchCold weather raises a solar panel's voltage. See how the Voc temperature coefficient works, which temperature to use, and real numbers for nine US cities.3 min readHot weather and the MPPT minimum: why a string can be too shortHot cells lower a panel's operating voltage. Estimate cell temperature from NMOT, see how far Vmp drops, and find the shortest string that works.3 min readHow to read solar panel and inverter datasheetsThe datasheet numbers that decide whether a panel and inverter work together: Voc, Vmp, Isc, temperature coefficients, NMOT and MPPT limits.3 min readSeries vs parallel: strings, MPPT inputs and current limitsHow series and parallel wiring change voltage and current, how many strings an MPPT input takes, when strings need fuses, and bifacial current.3 min readDC/AC ratio and inverter clipping: how much to oversizeWhat the DC-to-AC ratio is, why most solar arrays are bigger than their inverter, how clipping works, and the inverter limits that cap the ratio.3 min readMicroinverters vs string inverters vs optimizers: how sizing differsHow string inverters, microinverters (Enphase, Hoymiles, APsystems) and SolarEdge optimizer systems are sized differently, with the checks that matter for each.3 min read
Code and wiring
NEC 690.7 explained: maximum PV system voltageHow NEC 690.7 sets a solar array's maximum DC voltage: the coefficient method, Table 690.7(A), engineered design and the 600 V and 1000 V limits.3 min readSolar wire sizing and voltage drop: a practical guideHow to size PV source circuit conductors under NEC 690.8 (the 156% rule), apply temperature correction, check voltage drop, and decide when strings need fuses.3 min readThe 120% rule for solar, explainedHow the NEC 120% busbar rule limits a solar backfeed breaker, why 7.6 kW inverters are so common, and what to do when a system does not fit.3 min read
Energy and money
Peak sun hours explained, with state-by-state numbersWhat peak sun hours are, how they differ from daylight hours, how to turn them into yearly solar production, and typical values by US state from NREL data.3 min readHow solar payback is calculated, and why it varies by stateHow to calculate solar payback, what changes it (rates, sun, cost, net metering) and 2026 state examples after the federal tax credit ended.3 min read