Home › Solar panels › HT-SAAE HT60-18X-440
HT-SAAE HT60-18X-440 illustration
HT-SAAE

HT60-18X-440

A 440 W monocrystalline silicon residential module with Voc 41.03 V, Isc 13.76 A and a -0.373 %/°C temperature coefficient. Electrical data from the California Energy Commission test list.

Rated power440 W
UseResidential
Voc / Isc41.03 V · 13.76 A
Pmax temp. coeff.-0.373 %/°C
Vmp / Imp34.48 V · 12.77 A
NOCT45.9 °C

Inverter compatibility

Works with 7 of 105 inverters in the database, at a −10 °C record low and a 40 °C hottest day. Open any row to use your own city.

InverterResult
Enphase IQ8PLUS-72-2-USMicroinverterNot compatible: MPPT window, hot daySize it →
Enphase IQ8M-72-2-USMicroinverterNot compatible: MPPT window, hot daySize it →
Enphase IQ8A-72-2-USMicroinverterNot compatible: MPPT window, hot daySize it →
Enphase IQ8H-240-72-2-USMicroinverterNot compatible: MPPT window, hot daySize it →
APsystems DS3-SMicroinverterNot compatible: MPPT window, hot daySize it →
APsystems DS3-LMicroinverterNot compatible: MPPT window, hot daySize it →
APsystems DS3MicroinverterNot compatible: MPPT window, hot daySize it →
SolarEdge SE3800H-USSolarEdge inverter8–13 panels per string with S440 (best 12)Size it →
SolarEdge SE6000H-USSolarEdge inverter8–12 panels per string with S440 (best 12)Size it →
SolarEdge SE7600H-USSolarEdge inverter8–15 panels per string with S440 (best 12)Size it →
SolarEdge SE10000H-USSolarEdge inverter8–15 panels per string with S440 (best 12)Size it →
SolarEdge SE11400H-USSolarEdge inverter8–15 panels per string with S440 (best 12)Size it →
Tesla Powerwall 3Hybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Sol-Ark Limitless 15K-2PHybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
EG4 18kPV-12LVHybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
CPS (Chint Power) SCA60KTL-DO/US-480String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Enphase IQ8P-72-2-USMicroinverterNot compatible: MPPT window, hot daySize it →
Sol-Ark 12K-2P-LLHybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
EG4 FlexBOSS21Hybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
EG4 6000XPHybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Fronius Primo GEN24 7.7 PlusHybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SolarEdge SE3000H-USSolarEdge inverter8–10 panels per string with S440 (best 10)Size it →
SolarEdge SE5000H-USSolarEdge inverter8–17 panels per string with S440 (best 12)Size it →
Hoymiles HMS-2000-4T-NAMicroinverterNot compatible: MPPT window, hot daySize it →
Hoymiles HMS-1600-4T-NAMicroinverterNot compatible: MPPT window, hot daySize it →
Fronius Primo 3.8-1String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Fronius Primo 7.6-1String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Fronius Primo 10.0-1String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Fronius Primo 15.0-1String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Tesla Solar Inverter 7.6 kWString inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Tesla Solar Inverter 3.8 kWString inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Enphase IQ8X-80-M-USMicroinverterNot compatible: MPPT window, hot daySize it →
CPS (Chint Power) SCA25KTL-DO/US-208String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
CPS (Chint Power) SCA36KTL-DO/US-480String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Enphase IQ8-60-2-USMicroinverterNot compatible: MPPT window, hot daySize it →
Enphase IQ8H-208-72-2-USMicroinverterNot compatible: MPPT window, hot daySize it →
Enphase IQ8MC-72-M-USMicroinverterNot compatible: MPPT window, hot daySize it →
Enphase IQ7-60-2-USMicroinverterNot compatible: MPPT window, hot daySize it →
Enphase IQ7PLUS-72-2-USMicroinverterNot compatible: MPPT window, hot daySize it →
Enphase IQ7X-96-2-USMicroinverterNot compatible: MPPT window, hot daySize it →
Enphase IQ7A-72-2-USMicroinverterNot compatible: MPPT window, hot daySize it →
Hoymiles HMS-1800-4T-NAMicroinverterNot compatible: MPPT window, hot daySize it →
Hoymiles HMS-700-2T-NAMicroinverterNot compatible: MPPT window, hot daySize it →
Hoymiles HMS-800-2T-NAMicroinverterNot compatible: MPPT window, hot daySize it →
Hoymiles HMS-900-2T-NAMicroinverterNot compatible: MPPT window, hot daySize it →
Hoymiles HMS-1000-2T-NAMicroinverterNot compatible: MPPT window, hot daySize it →
Hoymiles HMS-350-1T-NAMicroinverterNot compatible: MPPT window, hot daySize it →
Hoymiles HMS-400-1T-NAMicroinverterNot compatible: MPPT window, hot daySize it →
Hoymiles HMS-450-1T-NAMicroinverterNot compatible: MPPT window, hot daySize it →
Hoymiles HMS-500-1T-NAMicroinverterNot compatible: MPPT window, hot daySize it →
Fronius Primo 6.0-1String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Fronius Primo 8.2-1String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Fronius Primo 11.4-1String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Fronius Primo 12.5-1String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB3.0-1SP-US-41String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB3.8-1SP-US-41String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB5.0-1SP-US-41String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB6.0-1SP-US-41String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB7.0-1SP-US-41String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB7.7-1SP-US-41String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB3.0-1SP-US-40String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB3.8-1SP-US-40String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB5.0-1SP-US-40String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB6.0-1SP-US-40String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB7.0-1SP-US-40String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB7.7-1SP-US-40String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA STP 33-US-41String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA STP 50-US-41String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA STP 62-US-41String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
CPS (Chint Power) SCA50KTL-DO/US-480String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Fronius Symo 15.0-3 480String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Fronius Symo 17.5-3 480String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Fronius Symo 20.0-3 480String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Fronius Symo 22.7-3 480String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Fronius Symo 24.0-3 480String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Sol-Ark 5K-1P-NHybrid inverterNot compatible: no string length fitsSize it →
Sol-Ark 8K-2P-NHybrid inverterNot compatible: no string length fitsSize it →
Sol-Ark 30K-3P-208VHybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Sol-Ark 60K-3P-480VHybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
EG4 FlexBOSS18Hybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
EG4 12000XPHybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Tesla Powerwall+Hybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Enphase IQ8HC-72-M-USMicroinverterNot compatible: MPPT window, hot daySize it →
APsystems QS1MicroinverterNot compatible: MPPT window, hot daySize it →
APsystems YC600MicroinverterNot compatible: MPPT window, hot daySize it →
Fronius Primo GEN24 3.8 PlusHybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Fronius Primo GEN24 5.0 PlusHybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Fronius Primo GEN24 6.0 PlusHybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Fronius Primo GEN24 10.0 PlusHybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SBSE3.8-US-50Hybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SBSE4.8-US-50Hybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SBSE5.8-US-50Hybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SBSE7.7-US-50Hybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SBSE9.6-US-50Hybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SBSE11.5-US-50Hybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Solis S6-GC25K-USString inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Solis S6-GC33K-USString inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Solis S6-GC36K-USString inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Solis S6-GC40K-USString inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Solis S6-GC50K-USString inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Solis S6-GC60K-USString inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Solis S5-GC60K-LV-USString inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Solis S5-GC75K-USString inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Solis S5-GC125K-USString inverterNot compatible: module Isc is above the per-MPPT limitSize it →
NEP BDM-600XMicroinverterNot compatible: MPPT window, hot daySize it →

Full specifications

Overview
BrandHT-SAAE
ModelHT60-18X-440
Cell technologyMonocrystalline silicon
Cells—
BifacialNo
Made in—
Electrical (STC)
Rated power (Pmax)440 W
Module efficiency—
Power tolerance—
Open-circuit voltage (Voc)41.03 V
Short-circuit current (Isc)13.76 A
Voltage at max power (Vmp)34.48 V
Current at max power (Imp)12.77 A
Max system voltage—
Max series fuse—
Temperature
Pmax temperature coefficient-0.373 %/°C
Voc temperature coefficient-0.255 %/°C
Isc temperature coefficient45.9 %/°C
NMOT / NOCT45.9 °C (NOCT (CEC test))
Operating temperature—
Mechanical & look
Dimensions—
Weight—
Mechanical load—
Appearance—
Frame—
Rear side—
Front glass—
Junction box—
Connector—
Cable length (+ / −)—
Fire rating—
Warranty
Warranty—
Degradation—
NotesElectrical values from the California Energy Commission PV module list (via the NREL SAM library). Size, weight, max system voltage and fuse rating: see the manufacturer datasheet.