Home › Solar panels › Risen RSM110-8-535BMDG
Risen RSM110-8-535BMDG drawn to scale
Risen · older model

RSM110-8-535BMDG

A 535 W monocrystalline silicon utility-scale module at 20.5% efficiency, 2384 × 1096 mm and 33.5 kg with Voc 37.66 V, Isc 18.07 A and a -0.327 %/°C temperature coefficient, glass rear (bifacial). Bifacial. Electrical data from the California Energy Commission test list.

Rated power535 W
Efficiency20.5%
Voc / Isc37.66 V · 18.07 A
Pmax temp. coeff.-0.327 %/°C
Vmp / Imp31.36 V · 17.07 A
Weight33.5 kg

Inverter compatibility

Works with 77 of 105 inverters in the database, at a −10 °C record low and a 40 °C hottest day with 10% bifacial gain. Open any row to use your own city.

InverterResult
Enphase IQ8PLUS-72-2-USMicroinverter1 panel per unit, 13 units per 20 A branch (check: MPPT window, hot day)Size it →
Enphase IQ8M-72-2-USMicroinverter1 panel per unit, 11 units per 20 A branch (check: MPPT window, hot day)Size it →
Enphase IQ8A-72-2-USMicroinverter1 panel per unit, 11 units per 20 A branch (check: MPPT window, hot day)Size it →
Enphase IQ8H-240-72-2-USMicroinverter1 panel per unit, 10 units per 20 A branch (check: MPPT window, hot day)Size it →
APsystems DS3-SMicroinverter2 panels per unit, 6 units per 20 A branch (check: Input current)Size it →
APsystems DS3-LMicroinverter2 panels per unit, 5 units per 20 A branch (check: Input current)Size it →
APsystems DS3Microinverter2 panels per unit, 4 units per 20 A branch (check: MPPT window, hot day)Size it →
SolarEdge SE3800H-USSolarEdge inverterNot compatible: Module power (all SolarEdge optimizers)Size it →
SolarEdge SE6000H-USSolarEdge inverterNot compatible: Module power (all SolarEdge optimizers)Size it →
SolarEdge SE7600H-USSolarEdge inverterNot compatible: Module power (all SolarEdge optimizers)Size it →
SolarEdge SE10000H-USSolarEdge inverterNot compatible: Module power (all SolarEdge optimizers)Size it →
SolarEdge SE11400H-USSolarEdge inverterNot compatible: Module power (all SolarEdge optimizers)Size it →
Tesla Powerwall 3Hybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Sol-Ark Limitless 15K-2PHybrid inverter6–11 panels per string (best 11)Size it →
EG4 18kPV-12LVHybrid inverter6–14 panels per string (best 14)Size it →
CPS (Chint Power) SCA60KTL-DO/US-480String inverter11–23 panels per string (best 23)Size it →
Enphase IQ8P-72-2-USMicroinverter1 panel per unit, 8 units per 20 A branch (check: MPPT window, hot day)Size it →
Sol-Ark 12K-2P-LLHybrid inverter6–11 panels per string (best 11)Size it →
EG4 FlexBOSS21Hybrid inverter7–14 panels per string (best 12)Size it →
EG4 6000XPHybrid inverter5–11 panels per string (best 10)Size it →
Fronius Primo GEN24 7.7 PlusHybrid inverter3–14 panels per string (best 13)Size it →
SolarEdge SE3000H-USSolarEdge inverterNot compatible: Module power (all SolarEdge optimizers)Size it →
SolarEdge SE5000H-USSolarEdge inverterNot compatible: Module power (all SolarEdge optimizers)Size it →
Hoymiles HMS-2000-4T-NAMicroinverter4 panels per unit, 2 units per 20 A branch (check: Input current)Size it →
Hoymiles HMS-1600-4T-NAMicroinverter4 panels per unit, 2 units per 20 A branch (check: Input current)Size it →
Fronius Primo 3.8-1String inverter4–14 panels per string (best 13)Size it →
Fronius Primo 7.6-1String inverter4–14 panels per string (best 13)Size it →
Fronius Primo 10.0-1String inverter4–23 panels per string (best 22)Size it →
Fronius Primo 15.0-1String inverter4–23 panels per string (best 22)Size it →
Tesla Solar Inverter 7.6 kWString inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Tesla Solar Inverter 3.8 kWString inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Enphase IQ8X-80-M-USMicroinverterNot compatible: Module short-circuit currentSize it →
CPS (Chint Power) SCA25KTL-DO/US-208String inverter11–23 panels per string (best 23)Size it →
CPS (Chint Power) SCA36KTL-DO/US-480String inverter11–23 panels per string (best 23)Size it →
Enphase IQ8-60-2-USMicroinverter1 panel per unit, 16 units per 20 A branch (check: MPPT window, hot day)Size it →
Enphase IQ8H-208-72-2-USMicroinverter1 panel per unit, 9 units per 20 A branch (check: MPPT window, hot day)Size it →
Enphase IQ8MC-72-M-USMicroinverter1 panel per unit, 12 units per 20 A branch (check: Module power pairing)Size it →
Enphase IQ7-60-2-USMicroinverterNot compatible: Module short-circuit currentSize it →
Enphase IQ7PLUS-72-2-USMicroinverterNot compatible: Module short-circuit currentSize it →
Enphase IQ7X-96-2-USMicroinverterNot compatible: Start-up voltageSize it →
Enphase IQ7A-72-2-USMicroinverterNot compatible: Start-up voltageSize it →
Hoymiles HMS-1800-4T-NAMicroinverter4 panels per unit, 2 units per 20 A branch (check: Input current)Size it →
Hoymiles HMS-700-2T-NAMicroinverter2 panels per unit, 6 units per 20 A branch (check: Input current)Size it →
Hoymiles HMS-800-2T-NAMicroinverter2 panels per unit, 5 units per 20 A branch (check: Input current)Size it →
Hoymiles HMS-900-2T-NAMicroinverter2 panels per unit, 4 units per 20 A branch (check: Input current)Size it →
Hoymiles HMS-1000-2T-NAMicroinverter2 panels per unit, 4 units per 20 A branch (check: Input current)Size it →
Hoymiles HMS-350-1T-NAMicroinverter1 panel per unit, 12 units per 20 A branch (check: Input current)Size it →
Hoymiles HMS-400-1T-NAMicroinverter1 panel per unit, 10 units per 20 A branch (check: Input current)Size it →
Hoymiles HMS-450-1T-NAMicroinverter1 panel per unit, 9 units per 20 A branch (check: Input current)Size it →
Hoymiles HMS-500-1T-NAMicroinverter1 panel per unit, 8 units per 20 A branch (check: Input current)Size it →
Fronius Primo 6.0-1String inverter4–14 panels per string (best 13)Size it →
Fronius Primo 8.2-1String inverter4–14 panels per string (best 13)Size it →
Fronius Primo 11.4-1String inverter4–23 panels per string (best 22)Size it →
Fronius Primo 12.5-1String inverter4–23 panels per string (best 22)Size it →
SMA SB3.0-1SP-US-41String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB3.8-1SP-US-41String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB5.0-1SP-US-41String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB6.0-1SP-US-41String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB7.0-1SP-US-41String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB7.7-1SP-US-41String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB3.0-1SP-US-40String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB3.8-1SP-US-40String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB5.0-1SP-US-40String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB6.0-1SP-US-40String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB7.0-1SP-US-40String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA SB7.7-1SP-US-40String inverterNot compatible: module Isc is above the per-MPPT limitSize it →
SMA STP 33-US-41String inverter6–23 panels per string (best 23)Size it →
SMA STP 50-US-41String inverter6–23 panels per string (best 23)Size it →
SMA STP 62-US-41String inverter6–23 panels per string (best 23)Size it →
CPS (Chint Power) SCA50KTL-DO/US-480String inverter11–23 panels per string (best 23)Size it →
Fronius Symo 15.0-3 480String inverter8–23 panels per string (best 22)Size it →
Fronius Symo 17.5-3 480String inverter8–23 panels per string (best 22)Size it →
Fronius Symo 20.0-3 480String inverter8–23 panels per string (best 22)Size it →
Fronius Symo 22.7-3 480String inverter8–23 panels per string (best 22)Size it →
Fronius Symo 24.0-3 480String inverter8–23 panels per string (best 22)Size it →
Sol-Ark 5K-1P-NHybrid inverter6–11 panels per string (best 11)Size it →
Sol-Ark 8K-2P-NHybrid inverter6–11 panels per string (best 11)Size it →
Sol-Ark 30K-3P-208VHybrid inverter6–13 panels per string (best 13)Size it →
Sol-Ark 60K-3P-480VHybrid inverter6–23 panels per string (best 23)Size it →
EG4 FlexBOSS18Hybrid inverter7–14 panels per string (best 12)Size it →
EG4 12000XPHybrid inverter5–11 panels per string (best 10)Size it →
Tesla Powerwall+Hybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Enphase IQ8HC-72-M-USMicroinverter1 panel per unit, 10 units per 20 A branch (check: MPPT window, hot day)Size it →
APsystems QS1Microinverter4 panels per unit, 3 units per 20 A branch (check: Input current)Size it →
APsystems YC600Microinverter2 panels per unit, 7 units per 20 A branch (check: Input current)Size it →
Fronius Primo GEN24 3.8 PlusHybrid inverter3–14 panels per string (best 13)Size it →
Fronius Primo GEN24 5.0 PlusHybrid inverter3–14 panels per string (best 13)Size it →
Fronius Primo GEN24 6.0 PlusHybrid inverter3–14 panels per string (best 13)Size it →
Fronius Primo GEN24 10.0 PlusHybrid inverter3–14 panels per string (best 13)Size it →
SMA SBSE3.8-US-50Hybrid inverter3–14 panels per string (best 13)Size it →
SMA SBSE4.8-US-50Hybrid inverter3–14 panels per string (best 13)Size it →
SMA SBSE5.8-US-50Hybrid inverter3–14 panels per string (best 13)Size it →
SMA SBSE7.7-US-50Hybrid inverter3–14 panels per string (best 13)Size it →
SMA SBSE9.6-US-50Hybrid inverter3–14 panels per string (best 13)Size it →
SMA SBSE11.5-US-50Hybrid inverter3–14 panels per string (best 13)Size it →
Solis S6-GC25K-USString inverter7–23 panels per string (best 23)Size it →
Solis S6-GC33K-USString inverter7–23 panels per string (best 23)Size it →
Solis S6-GC36K-USString inverter7–23 panels per string (best 23)Size it →
Solis S6-GC40K-USString inverter7–23 panels per string (best 23)Size it →
Solis S6-GC50K-USString inverter7–23 panels per string (best 23)Size it →
Solis S6-GC60K-USString inverter7–23 panels per string (best 23)Size it →
Solis S5-GC60K-LV-USString inverter7–23 panels per string (best 23)Size it →
Solis S5-GC75K-USString inverter7–23 panels per string (best 23)Size it →
Solis S5-GC125K-USString inverter7–23 panels per string (best 23)Size it →
NEP BDM-600XMicroinverter2 panels per unit, 6 units per 20 A branch (check: Input current)Size it →

Full specifications

Overview
BrandRisen
ModelRSM110-8-535BMDG
Cell technologyMonocrystalline silicon
Cells110 cut cells, PERC (210 mm)
BifacialYes
Made in—
Electrical (STC)
Rated power (Pmax)535 W
Module efficiency20.50 %
Power tolerance—
Open-circuit voltage (Voc)37.66 V
Short-circuit current (Isc)18.07 A
Voltage at max power (Vmp)31.36 V
Current at max power (Imp)17.07 A
Max system voltage1,500 V
Max series fuse35 A
Temperature
Pmax temperature coefficient-0.327 %/°C
Voc temperature coefficient-0.341 %/°C
Isc temperature coefficient0.018 %/°C
NMOT / NOCT45.2 °C (NOCT (CEC test))
Operating temperature—
Mechanical & look
Dimensions2384 × 1096 × 30 mm (93.9 × 43.1 × 1.18 in)
Weight33.5 kg (73.9 lb)
Mechanical load—
AppearanceGlass rear (bifacial)
Frame—
Rear side—
Front glass—
Junction box—
Connector—
Cable length (+ / −)—
Fire rating—
Warranty
Warranty12 yr product · 30 yr performance
Degradation—
NotesOlder model, listed for replacements. Electrical values from the California Energy Commission PV module list (independently tested). Size, weight and ratings from the manufacturer datasheet.