Home › Solar panels › URE FBF420DFG-BB
URE FBF420DFG-BB illustration
URE

FBF420DFG-BB

A 420 W monocrystalline silicon residential module with Voc 38.11 V, Isc 14.07 A and a -0.295 %/°C temperature coefficient, glass rear (bifacial). Bifacial. Electrical data from the California Energy Commission test list.

Rated power420 W
UseResidential
Voc / Isc38.11 V · 14.07 A
Pmax temp. coeff.-0.295 %/°C
Vmp / Imp31.52 V · 13.32 A
NOCT45 °C

Inverter compatibility

Works with 92 of 105 inverters in the database, at a −10 °C record low and a 40 °C hottest day with 10% bifacial gain. Open any row to use your own city.

InverterResult
Enphase IQ8PLUS-72-2-USMicroinverter1 panel per unit, 13 units per 20 A branch (check: MPPT window, hot day)Size it →
Enphase IQ8M-72-2-USMicroinverter1 panel per unit, 11 units per 20 A branch (check: MPPT window, hot day)Size it →
Enphase IQ8A-72-2-USMicroinverter1 panel per unit, 11 units per 20 A branch (check: MPPT window, hot day)Size it →
Enphase IQ8H-240-72-2-USMicroinverter1 panel per unit, 10 units per 20 A branch (check: MPPT window, hot day)Size it →
APsystems DS3-SMicroinverter2 panels per unit, 6 units per 20 A branchSize it →
APsystems DS3-LMicroinverter2 panels per unit, 5 units per 20 A branchSize it →
APsystems DS3Microinverter2 panels per unit, 4 units per 20 A branch (check: MPPT window, hot day)Size it →
SolarEdge SE3800H-USSolarEdge inverterNot compatible: Module short-circuit current (all SolarEdge optimizers)Size it →
SolarEdge SE6000H-USSolarEdge inverterNot compatible: Module short-circuit current (all SolarEdge optimizers)Size it →
SolarEdge SE7600H-USSolarEdge inverterNot compatible: Module short-circuit current (all SolarEdge optimizers)Size it →
SolarEdge SE10000H-USSolarEdge inverterNot compatible: Module short-circuit current (all SolarEdge optimizers)Size it →
SolarEdge SE11400H-USSolarEdge inverterNot compatible: Module short-circuit current (all SolarEdge optimizers)Size it →
Tesla Powerwall 3Hybrid inverterNot compatible: module Isc is above the per-MPPT limitSize it →
Sol-Ark Limitless 15K-2PHybrid inverter6–12 panels per string (best 12)Size it →
EG4 18kPV-12LVHybrid inverter6–14 panels per string (best 14)Size it →
CPS (Chint Power) SCA60KTL-DO/US-480String inverter10–24 panels per string (best 24)Size it →
Enphase IQ8P-72-2-USMicroinverter1 panel per unit, 8 units per 20 A branch (check: MPPT window, hot day)Size it →
Sol-Ark 12K-2P-LLHybrid inverter6–12 panels per string (best 12)Size it →
EG4 FlexBOSS21Hybrid inverter6–14 panels per string (best 12)Size it →
EG4 6000XPHybrid inverter5–11 panels per string (best 10)Size it →
Fronius Primo GEN24 7.7 PlusHybrid inverter3–14 panels per string (best 13)Size it →
SolarEdge SE3000H-USSolarEdge inverterNot compatible: Module short-circuit current (all SolarEdge optimizers)Size it →
SolarEdge SE5000H-USSolarEdge inverterNot compatible: Module short-circuit current (all SolarEdge optimizers)Size it →
Hoymiles HMS-2000-4T-NAMicroinverter4 panels per unit, 2 units per 20 A branchSize it →
Hoymiles HMS-1600-4T-NAMicroinverter4 panels per unit, 2 units per 20 A branch (check: Input current)Size it →
Fronius Primo 3.8-1String inverter3–14 panels per string (best 13)Size it →
Fronius Primo 7.6-1String inverter3–14 panels per string (best 13)Size it →
Fronius Primo 10.0-1String inverter3–24 panels per string (best 22)Size it →
Fronius Primo 15.0-1String inverter3–24 panels per string (best 22)Size it →
Tesla Solar Inverter 7.6 kWString inverter3–14 panels per string (best 13)Size it →
Tesla Solar Inverter 3.8 kWString inverter3–14 panels per string (best 13)Size it →
Enphase IQ8X-80-M-USMicroinverterNot compatible: Module short-circuit currentSize it →
CPS (Chint Power) SCA25KTL-DO/US-208String inverter10–24 panels per string (best 24)Size it →
CPS (Chint Power) SCA36KTL-DO/US-480String inverter10–24 panels per string (best 24)Size it →
Enphase IQ8-60-2-USMicroinverter1 panel per unit, 16 units per 20 A branch (check: MPPT window, hot day)Size it →
Enphase IQ8H-208-72-2-USMicroinverter1 panel per unit, 9 units per 20 A branch (check: MPPT window, hot day)Size it →
Enphase IQ8MC-72-M-USMicroinverter1 panel per unit, 12 units per 20 A branchSize it →
Enphase IQ7-60-2-USMicroinverterNot compatible: Module short-circuit currentSize it →
Enphase IQ7PLUS-72-2-USMicroinverterNot compatible: Module short-circuit currentSize it →
Enphase IQ7X-96-2-USMicroinverterNot compatible: Module short-circuit currentSize it →
Enphase IQ7A-72-2-USMicroinverterNot compatible: Module short-circuit currentSize it →
Hoymiles HMS-1800-4T-NAMicroinverter4 panels per unit, 2 units per 20 A branchSize it →
Hoymiles HMS-700-2T-NAMicroinverter2 panels per unit, 6 units per 20 A branch (check: Input current)Size it →
Hoymiles HMS-800-2T-NAMicroinverter2 panels per unit, 5 units per 20 A branch (check: Input current)Size it →
Hoymiles HMS-900-2T-NAMicroinverter2 panels per unit, 4 units per 20 A branchSize it →
Hoymiles HMS-1000-2T-NAMicroinverter2 panels per unit, 4 units per 20 A branchSize it →
Hoymiles HMS-350-1T-NAMicroinverter1 panel per unit, 12 units per 20 A branch (check: Input current)Size it →
Hoymiles HMS-400-1T-NAMicroinverter1 panel per unit, 10 units per 20 A branch (check: Input current)Size it →
Hoymiles HMS-450-1T-NAMicroinverter1 panel per unit, 9 units per 20 A branchSize it →
Hoymiles HMS-500-1T-NAMicroinverter1 panel per unit, 8 units per 20 A branchSize it →
Fronius Primo 6.0-1String inverter3–14 panels per string (best 13)Size it →
Fronius Primo 8.2-1String inverter3–14 panels per string (best 13)Size it →
Fronius Primo 11.4-1String inverter3–24 panels per string (best 22)Size it →
Fronius Primo 12.5-1String inverter3–24 panels per string (best 22)Size it →
SMA SB3.0-1SP-US-41String inverter4–14 panels per string (best 14)Size it →
SMA SB3.8-1SP-US-41String inverter4–14 panels per string (best 14)Size it →
SMA SB5.0-1SP-US-41String inverter4–14 panels per string (best 14)Size it →
SMA SB6.0-1SP-US-41String inverter4–14 panels per string (best 14)Size it →
SMA SB7.0-1SP-US-41String inverter4–14 panels per string (best 14)Size it →
SMA SB7.7-1SP-US-41String inverter4–14 panels per string (best 14)Size it →
SMA SB3.0-1SP-US-40String inverter4–14 panels per string (best 14)Size it →
SMA SB3.8-1SP-US-40String inverter4–14 panels per string (best 14)Size it →
SMA SB5.0-1SP-US-40String inverter4–14 panels per string (best 14)Size it →
SMA SB6.0-1SP-US-40String inverter4–14 panels per string (best 14)Size it →
SMA SB7.0-1SP-US-40String inverter4–14 panels per string (best 14)Size it →
SMA SB7.7-1SP-US-40String inverter4–14 panels per string (best 14)Size it →
SMA STP 33-US-41String inverter6–24 panels per string (best 24)Size it →
SMA STP 50-US-41String inverter6–24 panels per string (best 24)Size it →
SMA STP 62-US-41String inverter6–24 panels per string (best 24)Size it →
CPS (Chint Power) SCA50KTL-DO/US-480String inverter10–24 panels per string (best 24)Size it →
Fronius Symo 15.0-3 480String inverter8–24 panels per string (best 22)Size it →
Fronius Symo 17.5-3 480String inverter8–24 panels per string (best 22)Size it →
Fronius Symo 20.0-3 480String inverter8–24 panels per string (best 22)Size it →
Fronius Symo 22.7-3 480String inverter8–24 panels per string (best 22)Size it →
Fronius Symo 24.0-3 480String inverter8–24 panels per string (best 22)Size it →
Sol-Ark 5K-1P-NHybrid inverter6–12 panels per string (best 12)Size it →
Sol-Ark 8K-2P-NHybrid inverter6–12 panels per string (best 12)Size it →
Sol-Ark 30K-3P-208VHybrid inverter6–13 panels per string (best 13)Size it →
Sol-Ark 60K-3P-480VHybrid inverter6–24 panels per string (best 24)Size it →
EG4 FlexBOSS18Hybrid inverter6–14 panels per string (best 12)Size it →
EG4 12000XPHybrid inverter5–11 panels per string (best 10)Size it →
Tesla Powerwall+Hybrid inverter3–14 panels per string (best 13)Size it →
Enphase IQ8HC-72-M-USMicroinverter1 panel per unit, 10 units per 20 A branch (check: MPPT window, hot day)Size it →
APsystems QS1Microinverter4 panels per unit, 3 units per 20 A branch (check: Input current)Size it →
APsystems YC600Microinverter2 panels per unit, 7 units per 20 A branch (check: Input current)Size it →
Fronius Primo GEN24 3.8 PlusHybrid inverter3–14 panels per string (best 13)Size it →
Fronius Primo GEN24 5.0 PlusHybrid inverter3–14 panels per string (best 13)Size it →
Fronius Primo GEN24 6.0 PlusHybrid inverter3–14 panels per string (best 13)Size it →
Fronius Primo GEN24 10.0 PlusHybrid inverter3–14 panels per string (best 13)Size it →
SMA SBSE3.8-US-50Hybrid inverter3–14 panels per string (best 13)Size it →
SMA SBSE4.8-US-50Hybrid inverter3–14 panels per string (best 13)Size it →
SMA SBSE5.8-US-50Hybrid inverter3–14 panels per string (best 13)Size it →
SMA SBSE7.7-US-50Hybrid inverter3–14 panels per string (best 13)Size it →
SMA SBSE9.6-US-50Hybrid inverter3–14 panels per string (best 13)Size it →
SMA SBSE11.5-US-50Hybrid inverter3–14 panels per string (best 13)Size it →
Solis S6-GC25K-USString inverter7–24 panels per string (best 24)Size it →
Solis S6-GC33K-USString inverter7–24 panels per string (best 24)Size it →
Solis S6-GC36K-USString inverter7–24 panels per string (best 24)Size it →
Solis S6-GC40K-USString inverter7–24 panels per string (best 24)Size it →
Solis S6-GC50K-USString inverter7–24 panels per string (best 24)Size it →
Solis S6-GC60K-USString inverter7–24 panels per string (best 24)Size it →
Solis S5-GC60K-LV-USString inverter7–24 panels per string (best 24)Size it →
Solis S5-GC75K-USString inverter7–24 panels per string (best 24)Size it →
Solis S5-GC125K-USString inverter7–24 panels per string (best 24)Size it →
NEP BDM-600XMicroinverter2 panels per unit, 6 units per 20 A branch (check: Input current)Size it →

Full specifications

Overview
BrandURE
ModelFBF420DFG-BB
Cell technologyMonocrystalline silicon
Cells—
BifacialYes
Made in—
Electrical (STC)
Rated power (Pmax)420 W
Module efficiency—
Power tolerance—
Open-circuit voltage (Voc)38.11 V
Short-circuit current (Isc)14.07 A
Voltage at max power (Vmp)31.52 V
Current at max power (Imp)13.32 A
Max system voltage—
Max series fuse—
Temperature
Pmax temperature coefficient-0.295 %/°C
Voc temperature coefficient-0.237 %/°C
Isc temperature coefficient0.037 %/°C
NMOT / NOCT45 °C (NOCT (CEC test))
Operating temperature—
Mechanical & look
Dimensions—
Weight—
Mechanical load—
AppearanceGlass rear (bifacial)
Frame—
Rear side—
Front glass—
Junction box—
Connector—
Cable length (+ / −)—
Fire rating—
Warranty
Warranty—
Degradation—
NotesElectrical values from the California Energy Commission PV module list (independently tested, via the NREL SAM library). Size, weight, max system voltage and fuse rating are not in that list; see the manufacturer datasheet.

Similar panels